All about product
Description
Specification
Reviews 0
Questions0

0 Leave a review
Product Code: FA94-38653-94
In Stock
92 грн.
Buy this product in 1 click:
Main specifications
Battery storage temperature, °C: -25 ~ +50
Charge operating temperature, °C: -20 ~ +50
Charging voltage (buffer mode), V: 6.75-6.9
Charging voltage (cyclic mode), V: 7.35-7.5
Discharge operating temperature, °C: -20 ~ +50
All specifications
We will deliver this product:
Payment
Description

AGM Lead-Acid Battery

An external universal battery made with AGM technology is a fully sealed external power source that requires no maintenance during storage and operation.

The manufacturing technology for universal external AGM (absorbent glass mat) batteries involves an absorbent fiberglass separator inside the battery. Batteries of this type handle increased loads exceptionally well.

Advantages of AGM batteries:

  • The charge/discharge cycle life of an AGM battery is 400* (typically 5 years, depending on operating conditions).
  • The battery can be installed in residential premises. The absence of free liquid electrolyte between the plates and the fully sealed casing prevent acid leakage and guarantee no harmful fumes.
  • These batteries demonstrate stable performance in practical use when operating in low (-20°C) and high (+50°C) ambient temperatures.
  • In operation, an AGM lead-acid battery can withstand prolonged discharge, cyclic discharge, deep discharge, and high-current discharge.
  • Batteries of this type have low self-discharge rates during long-term storage and reliable self-protection against over-discharge and over-charge.

Features of AGM battery production

Inside an AGM battery, porous insulating separators of thin fiberglass are placed. The separators and electrode plates are tightly pressed against each other. Thus, there is no free liquid electrolyte between the battery plates, as it is contained within the separator and the active part of the electrodes.

The amount of liquid electrolyte is dosed so that small pores are filled with acid, while larger ones ensure gas circulation.

The battery design features an improved gas recombination system – oxygen and hydrogen, formed as a result of chemical processes, do not escape beyond the sealed casing before condensation.

Areas of application: why is an AGM lead-acid battery needed?

A universal external charging battery is used:

  • In telecommunication and other communication systems, including as an external battery for charging mobile phones, two-way radios, etc.
  • For equipment in video surveillance, security, burglar, fire, and other alarm systems.
  • In uninterruptible power supply systems for server stations.
  • As a power source for medical, laboratory, commercial, and other specialized equipment.
  • In energy storage systems from alternative sources (batteries for solar panels).
  • As a battery for emergency or LED luminaires.
  • As batteries for uninterruptible power supply units and UPS.

Which batteries are suitable for emergency lighting systems in Ukraine, and which battery should you buy for a UPS?

The choice of battery depends on the power of the consumers to be connected, as well as the required autonomous operating time of the electrical equipment from the battery.

An external AGM battery for a UPS must have sufficient capacity, a wide range of operating temperatures, and a long service life.

Before deciding which battery is best to buy for a UPS, carefully study the parameters of the uninterruptible power supply and determine the amount of time required for autonomous operation of the electrical equipment.

AGM batteries are in high demand among consumers who want to buy an inexpensive and versatile battery for a heating boiler, emergency lighting systems, or autonomous water supply.

Before choosing a battery for solar panels, uninterruptible power supplies, or other purposes, consult a specialist.

How to avoid battery capacity loss in conditions of frequent power outages?

Two important rules for caring for AGM, GEL, MG batteries:

  1. Do not frequently discharge the battery by more than 30% of its capacity (consider this when calculating battery capacity)
  2. After discharge, the battery must be fully charged with a current of 1/10 of its capacity for 10 hours

IMPORTANT! If a group of several batteries is used, connected in parallel or in series, then:

  • all batteries must have the same capacity,
  • be of the same type (AGM, GEL, or MG),
  • have the same voltage, the same number of charge/discharge cycles,
  • be from the same batch of the same brand.

Violation of these requirements leads to premature failure of one or more batteries and is not a warranty case. More detailed information can be found in our article.

On the official LogicPower website, you can order UPS batteries and other types of batteries with delivery across Ukraine. Price – directly from the manufacturer.

Warranty – 12 months.

The company ensures 100% fulfillment of warranty obligations. Technical maintenance and repair of LogicPower equipment are carried out in certified service centers.

*Depending on operating conditions

Specifications
Battery storage temperature, °C -25 ~ +50
Charge operating temperature, °C -20 ~ +50
Charging voltage (buffer mode), V 6.75-6.9
Charging voltage (cyclic mode), V 7.35-7.5
Discharge operating temperature, °C -20 ~ +50
Height with terminals, mm 55
Height, mm 51
Housing material Plastic
Internal resistance, mOm 50
Length, mm 97
Nominal capacity, Ah 1,3
Nominal charging current, A 0.13
Nominal voltage, V 6
Number of cycles 400
Short-circuit current, A 58.5
Terminal type T1
Type AGM Lead-Acid
Volume, m³ 0.000128
Warranty, months 6
Weight, kg 0.295
Width, mm 24
Reviews

There are no reviews for this product, be the first to leave your review.

Answers & questions

No questions about this product, be the first and ask your question.

Viewed Products
GV LiFePO4 Battery 12.8V - 6Ah (76Wh)
0
1 045 грн.
Add to Cart
In stock
Medresq Aluminum Traction Splint for Leg
0
2 530 грн.
Add to Cart
In stock