TMG POWER TMGB-25 Diesel Generator — a reliable solution for autonomous and emergency power supply to private, public, and commercial facilities. Manufacturer: TMG POWER. This unit generates a three-phase output voltage of 400 V and is designed for intensive use as both backup and continuous power supply.
Different parts of the technical description provide power ratings: the introduction states a nominal power of 25 kVA/20 kW, while the list of characteristics specifies: maximum power 25 kVA/20 kW, nominal power 22.7 kVA/18.1 kW. Both values are present in the documentation and provide an understanding of the unit's operating capabilities under continuous and peak loads.
Engine: a four-stroke universal generator engine Baudouin (French-made), ensuring high performance with moderate fuel consumption. The alternator with copper winding minimizes the risk of overheating and guarantees stable, high-quality electricity. An automatic voltage regulator (AVR) is included to maintain stable output parameters.
The unit's housing is a sound-absorbing, all-weather enclosure equipped with stiffening ribs; sound insulation is made of special fiberglass layers. The galvanized body, coated with powder polyester paint, protects mechanisms from corrosion and moisture ingress, allowing the generator to be installed outdoors without additional shelter. For operation in cold weather, automatic coolant preheating and automatic battery charging are provided.
Applications of the TMG POWER TMGB-25 Diesel Generator
The generator is suitable for powering various facilities, including:
- Private households
- Industrial enterprises
- Agricultural sector
- Office premises
- Banking institutions
- Medical facilities
- Other public and commercial facilities
Why choose the TMG POWER TMGB-25 Diesel Generator
Key features and benefits at a glance:
- Maximum power 25 kVA/20 kW, nominal power 22.7 kVA/18.1 kW (some sources also indicate a nominal rating of 25 kVA/20 kW)
- Three-phase output voltage 400 V
- 4-stroke universal Baudouin generator engine
- Copper winding alternator
- Automatic Voltage Regulator (AVR)
- Sound-absorbing, all-weather housing with stiffening ribs
- Fiberglass sound insulation
- Galvanized casing coated with powder polyester paint for corrosion protection
- Automatic Transfer Switch (ATS) included
- Automatic coolant preheating function
- Monitoring and automatic charging of the battery
- Convenient and intuitive DATAKOM control panel
- Remote monitoring of operating parameters (optional)
- Programming via USB, RS-232, and GSM (optional)
Advantages and Disadvantages of the TMG POWER TMGB-25 Diesel Generator
| Pros | Cons |
| Quite high power | Higher cost compared to options with budget Chinese engines |
| High-quality electricity | |
| Efficient use in all seasons | |
| Simple and intuitive control |
TMG POWER TMGB-25 Diesel Generator Package Contents
The standard package includes:
- Coolant heater
- Automatic charger
- Battery
- Automatic Transfer Switch (ATS)
How to properly use the TMG POWER TMGB-25 Diesel Generator
Operation must be carried out in accordance with the technical documentation and manufacturer's recommendations. Only a qualified specialist should install and start the generator. Our specialists can perform commissioning works with a client visit by arrangement.
Tips for Operation and Maintenance
Main prohibitions and recommendations for safe operation:
- Do not make changes to the design and mechanisms of the equipment
- Do not use open flames near a running generator
- Do not add fuel while the engine is running or still hot
- Do not mix different types of fuel and lubricants
Frequently Asked Questions
Below are answers to common questions about generators of this class:
Which power rating should I focus on - nominal or maximum?
Focus on the nominal power — this is the indicator that determines how much power the generator can produce continuously. Maximum power is a short-term reserve for peak loads.
What is the fuel consumption of industrial generators?
Fuel consumption depends on the generator's power, load, fuel quality, and other factors. Specific data is provided for a specific model upon request.
How to properly install and start the generator?
If you do not have the relevant knowledge and experience, we recommend contacting qualified specialists. Our specialists can visit to perform commissioning works.
How to calculate the required generator power for my facility?
Correct power calculation is complex and individual — we advise contacting our managers for professional selection and calculation.
What is the difference between air-cooled and liquid-cooled generators?
Air-cooled generators are not designed for continuous operation and require breaks for cooling. Liquid-cooled generators can operate for extended periods without breaks, which is why liquid cooling is typically used in powerful units.
Product category: Energy Independence > Generators
Other products in this category here Generators
There are no reviews for this product, be the first to leave your review.
No questions about this product, be the first and ask your question.