Main specifications
Coolant capacity: 16 L
Cooling: Liquid
Crankcase oil capacity: 13 L
Dimensions with housing (WxDxH): 2600x1000x1410 mm
Engine type: 4-cylinder inline
All specifications
We will deliver this product:
Payment
Description

The SOYGEN SGR 80 KVA diesel generator is a powerful and reliable generating set from the Turkish brand Soygen, designed to provide uninterrupted power supply to residential buildings, industrial and commercial facilities, medical institutions, educational institutions, agricultural enterprises, and commercial spaces. This three-phase generator with a galvanized steel casing and sound-absorbing fiberglass sheets ensures durable and relatively quiet operation in various climatic conditions.


Key Features


The SGR 80 model is designed for intensive use and has undergone quality control under load. Below are the technical parameters that determine its performance and scope of application.


Output Voltage230 V / 380 V
Maximum Power64 kW / 80 kVA
Rated Power58 kW / 72 kVA
Engine TypeInline, 4 cylinders
Speed1500 rpm
Start TypeAutomatic Start (AVR) + Electric Start
Fuel TypeDiesel
Fuel Consumption (100% / 75% / 50%)17 / 13 / 10 L/h
Fuel Tank Capacity4,087 L
Crankcase Oil Volume13 L
Engine Cooling SystemWater
Coolant Volume16 L
Compression Ratio18:01
Dimensions2600x1000x1410 mm
Weight1305 kg
Brand CountryTurkey

Who is this product suitable for?


The SGR 80 diesel generator is ideal for facilities requiring high and stable power and backup power at 230/380 V. Examples of applications include:


  • Residential buildings
  • Government and commercial institutions
  • Production facilities
  • Hospitals
  • Schools
  • Agriculture
  • Shops
  • Offices

Installation and Operation Instructions


To ensure safe and long-lasting operation of the generator, adhere to the installation and operation requirements. Installation, maintenance, and repair work should only be performed by qualified personnel.


Installation


  • 1. It is recommended to install the generator on a special foundation at least 200 mm high; the edges of the foundation should extend at least 150 mm beyond the frame; the mass of the foundation should be twice the mass of the generator.
  • 2. To avoid flooding, raise the unit 100 mm above ground level.
  • 3. Outdoors, the generator should be placed at a safe distance from buildings and underground utilities, with lightning protection provided.
  • 4. When installing indoors, observe distances: from walls — at least 1200 mm, from the highest point to the ceiling — at least 1500 mm; ensure ventilation and exhaust gas removal; the exit from the room must lead outside.
  • 5. Reliable grounding of the unit is mandatory.

Operation


  • 1. Before starting, check the fuel, oil, and coolant levels.
  • 2. During operation, the casing must be tightly closed.
  • 3. Use a high-quality electrical cable that matches the unit's power.
  • 4. Ensure no foreign objects are on moving parts.
  • 5. Check coolant and oil levels every 6–8 hours of operation.
  • 6. Do not overload the generator beyond its permissible power.
  • 7. Do not operate without load for more than 30 minutes.
  • 8. Avoid prolonged downtime of the unit.

Safety Precautions


  • 1. Do not store flammable materials near the generator.
  • 2. Smoking near the unit is strictly prohibited.
  • 3. Do not refuel the generator while it is running.
  • 4. Do not touch the equipment during operation.
  • 5. During maintenance, press the emergency stop button to prevent accidental auto-start.
  • 6. Be aware of the danger of exhaust gases — work in well-ventilated areas and avoid inhaling them.

Care and Maintenance


Regular maintenance will ensure stable operation of the SGR 80. Daily visual inspection, scheduled inspection of mechanical components, maintaining a log of technical inspections, and contacting a service center for preventive work are recommended.


Advantages of the SGR 80 Model


  • Rated power of 58 kW (72 kVA) for continuous power supply.
  • Supports two voltage types (230/380 V) for various consumers.
  • Automatic Voltage Regulator (AVR) maintains stable output.
  • High-quality windings withstand elevated temperatures.
  • Auto-start ensures instant connection when the grid goes down.
  • Economical fuel consumption and low noise with standard sound insulation.
  • Reliability in various weather conditions.

Pros and Cons


ProsCons
Supports 2 voltage typesStrict installation requirements
High powerRequires professional maintenance
Economical fuel consumption
Low noise level
Long continuous operation

Package Contents


The standard package of the SGR 80 diesel generator includes:


  • 12V DC starter motor
  • Battery
  • Brushless AC generator (IP23, insulation class H)
  • 50℃ radiator (standard equipment)
  • Control panel with key (standard equipment)
  • Warranty card

Compatibility


If units with different power are needed, consider the SOYGEN SGB110 KVA diesel generator (rated power 80 kW) or the less powerful SOYGEN SGB 50 KVA model (rated power 36 kW).


Frequently Asked Questions


How long can a diesel generator run continuously?


The duration of operation depends on operating conditions, load, and technical condition; generally, continuous use from several hours to a day or more is possible, provided correct maintenance and fuel availability.


How often should the oil be changed?


Oil change is usually recommended approximately every 500 hours of operation or about 6 months, but this may vary depending on the intensity of use.


Why can't fuel be added during operation?


Refueling during operation is dangerous due to the risk of fuel spilling onto hot components and potential ignition, so refueling should only be done after the engine has stopped.


Which generator is better for home — single-phase or three-phase?


If your home does not have 380 V equipment or it is rarely used, a single-phase unit is more appropriate; for production facilities and large objects, it is better to choose three-phase models, like the SGR 80.


What to choose — a diesel or gasoline generator?


Diesel generators are more durable and powerful, suitable for long-term intensive use, while gasoline generators are cheaper and appropriate for occasional low-power use.


Brand: Soygen. Product Category: Energy Independence > Generators.


Other products in this category here Generators

Specifications
Coolant capacity 16 L
Cooling Liquid
Crankcase oil capacity 13 L
Dimensions with housing (WxDxH) 2600x1000x1410 mm
Engine type 4-cylinder inline
Fuel consumption (100% x 75% x 50% prime mover) 17/13/10 h/person
Fuel tank capacity 4,087 UAH
Fuel Type Diesel
Guarantee 12 months
Launch type Automatic Voltage Regulation (AVR) + electric start
Max. Force 80 kVA/64 kW
Motor speed 1500 RPM
Nominal. Strength 72 kVA/58 kW
Voltage 400 V
Weight with housing 1305 kg