Buy this product in 1 click:
Main specifications
Battery storage temperature, °C: -20 ~ +50
Charge operating temperature, °C: -20 ~ +50
Charging voltage (buffer mode), V: 13.5-13.8
Charging voltage (cyclic mode), V: 14.5-14.9
Discharge operating temperature, °C: -20 ~ +50
All specifications
We will deliver this product:
Payment
Description

AGM Lead-Acid Battery for Alarm Systems

An external universal battery made with AGM technology – a fully sealed external power source that requires no maintenance during storage and operation.

The manufacturing technology for universal external AGM (absorbent glass mat) batteries involves an absorbent fiberglass separator inside the battery. Batteries of this type excel at handling increased loads.

Advantages of AGM batteries:

  • The charge/discharge cycle life of an AGM battery is 400* (typically 5 years, depending on operating conditions).
  • The battery can be installed in residential premises. The absence of free liquid electrolyte between the plates and the fully sealed casing prevent acid leakage and guarantee no harmful fumes.
  • These batteries demonstrate stable performance in practical use when operating in low (-20°C) and high (+50°C) ambient temperatures.
  • In operation, an AGM lead-acid battery can withstand prolonged discharge, cyclic discharge, deep discharge, and high-current discharge.
  • Batteries of this type have low self-discharge rates during long-term storage and reliable self-protection against over-discharge and over-charge.

Features of AGM Battery Production

Inside an AGM-technology battery, porous insulating separators of thin fiberglass are placed. The separators and electrode plates are tightly pressed against each other. Thus, no free liquid electrolyte remains between the battery plates, as it is contained within the separator and the active part of the electrodes.

The amount of liquid electrolyte is dosed so that small pores are filled with acid, while larger ones ensure gas circulation.

The battery design features an improved gas recombination system – oxygen and hydrogen, formed as a result of chemical processes, do not evaporate beyond the sealed casing before condensation.

Areas of Application: Why is an AGM Lead-Acid Battery Needed?

This battery is specifically designed for video surveillance and alarm systems and operates at low currents. Please use the battery as intended:

  • In telecommunication and other communication systems, including as an external battery for charging mobile phones, two-way radios, etc.
  • For equipment in video surveillance, security, burglar, fire, and other alarm systems.
  • As a power source for medical, laboratory, commercial, and other specialized equipment.
  • As a battery for emergency or LED lighting.

Which batteries are suitable for emergency lighting systems in Ukraine, and which battery should be bought for a UPS?

The choice of battery depends on the power of the connected consumers, as well as the required autonomous operating time of the electrical equipment from the battery.

An external AGM battery for a UPS must have sufficient capacity, a wide operating temperature range, and a long service life.

Before deciding which battery is best to buy for a UPS, carefully study the parameters of the uninterruptible power supply and determine the amount of time required for autonomous operation of the electrical equipment.

AGM batteries are in high demand among consumers who want to buy an inexpensive and versatile battery for a heating boiler, emergency lighting systems, or autonomous water supply.

How to avoid battery capacity loss in conditions of frequent power outages?

Two important rules for caring for AGM, GEL, MG batteries:

  1. Do not frequently discharge the battery by more than 30% of its capacity (consider this when calculating battery capacity)
  2. After discharge, the battery must be fully charged with a current of 1/10 of its capacity for 10 hours

IMPORTANT! If a group of several batteries connected in parallel or in series is used, then:

  • all batteries must have the same capacity,
  • be of the same type (AGM, GEL, or MG),
  • have the same voltage, the same number of charge/discharge cycles,
  • be from the same batch of the same brand.

Violation of these requirements leads to premature failure of one or more batteries and is not a warranty case. You can find more detailed information in our article.

Specifications
Battery storage temperature, °C -20 ~ +50
Charge operating temperature, °C -20 ~ +50
Charging voltage (buffer mode), V 13.5-13.8
Charging voltage (cyclic mode), V 14.5-14.9
Discharge operating temperature, °C -20 ~ +50
Height with terminals, mm 100
Height, mm 95
Housing material Plastic
Length, mm 150
Nominal capacity, Ah 7
Nominal charging current, A 0.7
Nominal voltage, V 12
Number of cycles 400
Short-circuit current, A 315
Terminal type T2
Type AGM Lead-Acid
Volume, m³ 0.000975
Warranty, months 6
Weight, kg 1.8
Width, mm 65