Main specifications
Battery storage temperature, °C: -20 ~ +50
Charge operating temperature, °C: -10 ~ +50
Charging voltage (buffer mode), V: 6.75-6.9
Charging voltage (cyclic mode), V: 7.35-7.5
Discharge operating temperature, °C: -15 ~ +50
All specifications
We will deliver this product:
Payment
Description

AGM Lead-Acid Battery

An external universal battery, manufactured using AGM technology, is a fully sealed external power source that requires no maintenance during storage and operation.

The manufacturing technology for universal external AGM (absorbent glass mat) batteries involves an absorbent fiberglass mat inside the battery. Batteries of this type handle increased loads exceptionally well.

Advantages of an AGM battery:

  • The charge/discharge cycle life of an AGM battery is 400* (generally 5 years, depending on operating conditions).
  • The battery can be installed in residential premises. The absence of free liquid electrolyte between the plates and the fully sealed casing prevent acid leakage and guarantee no harmful fumes.
  • In practical use, these batteries show stable results when operating in low (-20°C) and high (+50°C) ambient temperatures.
  • In operation, an AGM lead-acid battery can withstand prolonged discharge, cyclic discharge, deep discharge, and high-current discharge.
  • Batteries of this type have low self-discharge rates during long-term storage and reliable self-protection against over-discharge and over-charge.

Features of AGM battery production

Inside a battery manufactured using AGM technology, porous insulating mats of thin fiberglass are placed. The separators and electrode plates are tightly pressed against each other. Thus, there is no free liquid electrolyte between the battery plates, as it is contained within the separator and the active part of the electrodes.

The amount of liquid electrolyte is metered so that small pores are filled with acid, while larger ones ensure gas circulation.

The battery design features an improved gas recombination system – oxygen and hydrogen, formed as a result of chemical processes, do not evaporate outside the sealed casing before condensation.

Areas of application: why is an AGM lead-acid battery needed?

A universal external charging battery is used:

  • In telecommunication and other communication systems, including as an external battery for charging mobile phones, two-way radios, etc.
  • For equipment in video surveillance, security, burglar, fire, and other alarm systems.
  • In uninterruptible power supply systems for server stations.
  • As a power source for medical, laboratory, commercial, and other specialized equipment.
  • In energy storage systems from alternative sources (batteries for solar panels).
  • As a battery for emergency or LED luminaires.
  • As batteries for uninterruptible power supply units and UPS.

Which batteries are suitable for emergency lighting systems in Ukraine, and which battery should you buy for a UPS?

The choice of battery depends on the power of the consumers to be connected, as well as the required autonomous operating time of the electrical equipment from the battery.

An external AGM battery for a UPS must have sufficient capacity, a wide range of operating temperatures, and a long service life.

Before deciding which battery is best to buy for a UPS, carefully study the parameters of the uninterruptible power supply and determine the amount of time required for autonomous operation of the electrical equipment.

AGM batteries are in high demand among consumers who want to buy an inexpensive and universal battery for a heating boiler, emergency lighting systems, or autonomous water supply.

How to avoid battery capacity loss during frequent power outages?

Two important rules for caring for AGM, GEL, MG batteries:

  1. Do not frequently discharge the battery by more than 30% of its capacity (consider this when calculating battery capacity)
  2. After discharge, the battery must be fully charged with a current of 1/10 of its capacity for 10 hours

IMPORTANT! If a group of several batteries connected in parallel or in series is used, then:

  • all batteries must have the same capacity,
  • be of the same type (AGM, GEL, or MG),
  • have the same voltage, the same number of charge/discharge cycles,
  • be from the same batch of the same brand.

Violation of these requirements leads to premature failure of one or more batteries and is not a warranty case. You can find more detailed information in our article.

Specifications
Battery storage temperature, °C -20 ~ +50
Charge operating temperature, °C -10 ~ +50
Charging voltage (buffer mode), V 6.75-6.9
Charging voltage (cyclic mode), V 7.35-7.5
Discharge operating temperature, °C -15 ~ +50
Height with terminals, mm 100
Height, mm 96
Housing material Plastic
Length, mm 151
Nominal capacity, Ah 7.2
Nominal charging current, A 0.72
Nominal voltage, V 6
Number of cycles 400
Short-circuit current, A 324
Terminal type T2
Type AGM Lead-Acid
Volume, m³ 0.000513
Warranty, months 12
Weight, kg 1
Width, mm 34
Reviews

There are no reviews for this product, be the first to leave your review.

Answers & questions

No questions about this product, be the first and ask your question.

Viewed Products
AGM Battery LPM 6V - 5.2 Ah
0
337 грн.
Add to Cart
DP belt organizer, multicam
0
220 грн.
Add to Cart